Ace ESP Sensors

Specifications

There are four main components to the ACE Single Pressure Sensor system, the sensor and suitable motor adapter are mounted to the pump motor and go downhole, then a High Voltage Interface and a Surface readout are installed at the surface. An additional unit, the Discharge Tubing Assembly, is necessary for the Dual Pressure Sensor system.

Transducer Type:

  • Silicon Strain Gauge ( Standard and Midrange models)
  • Digital Strain Gauge ( Xtreme model)

Temperature Range (Instrument):

  • 32°F - 257°F / 0°C - 125°C - Standard Model
  • 32°F - 302°F / 0°C - 150°C – Midrange Model  
  • 32°F - 350°F / 0°C - 177°C – Xtreme Model  

Temperature Range (winding transducer):

  • 32°F - 600°F / 0°C – 316°C

Pressure Range:

  • 0-3,000 PSI & 0-5,000 PSI (Standard and Midrange)
  • 0-6,000 PSI & 0-8,000 PSI (Xtreme)

Pressure Accuracy:

  • 0.25% BFSL; 1% FS (Standard and Midrange)
  • 0.1% Typical; 0.2% FS (Xtreme)

Pressure Resolution

  • 0.1 PSI

Instrument Diameter:

  • 3.72”

Instrument Length:

  • 18.5"

Instrument Weight:

  • 35lbs / 15.9 kG

Instrument Metallurgy:

  • 1020 CS
  • 316 SS